Fluke Oc4usb Drivers For Mac
Posted : admin On 11.03.2020Features, Applications PC Requirements - USB 1.1 (or higher) port on the PC. Windows XP/2000/Me/98 Second Edition. Installing the USB-IR cable drivers - Log into an account with Administrator privileges (Windows XP or Windows 2000). Plug the USB cable into an USB port. Windows will respond that it has 'found new hardware', and the Windows Hardware Wizard dialog will appear. Insert the CD-ROM with the USB drivers (Included with cable or on FlukeView CD-ROM).

Click the 'Next' button on the Hardware Wizard dialog - The Hardware Wizard will find the drivers on the CD-ROM ('Prolific USB-to-serial bridge' on Windows XP/2000, or 'USB to Serial Port' on Windows 98SE/Me). Note: for Windows XP users, you may get a dialog box warning you that this driver 'has not passed Windows Logo Testing'.
Just click the 'Continue anyway' button. The Hardware Wizard will finish, the USB-IR cable drivers have now been installed. Your PC may need to reboot before the USB-IR cable can be used. Note on Windows XP/2000: if you attach the USB-IR cable to a different USB port on your PC, you will have to repeat the installation of the drivers. Determining the USB-IR Cable's COM port - Attach the cable to the PC.
Go to the Windows Control Panel. Open the 'System Properties' dialog box.
Open the Device Manager: On Windows 2000/XP, click on the 'Hardware' tab of the 'System Properties' dialog box and click on the 'Device Manager' button, On Windows 98SE/Me, click the 'Device Manager' tab. On the 'Device Manager' dialog box, look under the 'Ports (COM & LPT)' tree.
Fluke Oc4usb Drivers For Mac Os
The COM port associated with the USB-IR cable is listed there, as: 'Prolific USB-to-serial bridge' (Windows 2000/XP), 'USB to Serial Port' (Windows 98 SE/Me). Changing the COM port # Some programs require COM or 4 and the USB cable is often installed as COM 5 or higher. To change the assigned COM port number, do the following: - Open Device Manager. On the 'Device Manager' dialog box, look under the 'Ports (COM & LPT)' tree. Click on the 'Port Settings' tab. Click on the 'Advanced' button. On the bottom left side pull down the bar and select COM or 4 (NOTE: Choose one that dos not say 'in use' next to it).
Click 'OK' again. Notice that the device will show up as being on the same COM port that it was before (i.e., COM5), but will show up on the new port if you close the Device Manager and open it again. Close the Device Manager.
This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, contact your nearest Fluke Authorized Service Center to obtain return authorization information, then send the defective product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O.
Box 9090 Everett WA USA. Fluke Industrial B.V. Box 7600 AB Almelo The Netherlands Specifications Type of interface: Optically isolated serial to USB adapter Baudrate: 57.6 k Baud max Logic States: SPACE = 0, Light with wavelength 800 nm MARK =1, No light Handshake method: XON/XOFF, Software handshake only Environmental Meets requirements of MIL-T-28800D Type III, Class 3. Temperature Operating: +55 °C Storage: +70 °C Mechanical Cable length: Weight: 0.1 kg To locate an authorized service center, visit us on the World Wide Web: or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in USA and Canada +-200 in Europe +1-425-446-5500 from other countries © 2004 Fluke Corporation. All rights reserved. Printed in The Netherlands. All product names are trademarks of their respective companies.
You need to register to use this feature. Total Price SEK Call Galco now for an expert who can help you to get the items you need fast! I can only assume the marketing words “infrared” and “optical” are actually referring to the exact same technology behind each. What do I receive if I choose a calibrated product at Distrelec? Uploader: Date Added: 15 January 2018 File Size: 35.45 Mb Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X Downloads: 20622 Price: Free.Free Regsitration Required However, in no time did I find a clear view of the one in the first picture the one with the yellow writing showing the actual “two led lights” or whatever the hell they are or the same oc4usb as the most commonly found od4usb picture.

You will oc4usb two items appearing, one version without a calibration service item-nr. Products oc4usb are supplied with a Manufacturer certificate can be identified by the key feature below: Oc4usb Your message has been sent. JavaScript seems oc4usb be disabled in your browser. Sent using FedEx, orders must be placed before 3pm oc4usb Saturday delivery. Options apply to entry-level machines, precision machines, and 5-axis machines. An error occurred the shopping list s could not be oc4usb loaded.
All orders for calibrated items are non-cancellable and non-returnable. After the oc4usb has been placed oc4usb the calibrated version, the non-calibrated device will be sent out from our warehouse to the calibration institute of Intertek Calibration service in process at Oc4usb Creating the certificate for end user The device will be repacked and sent directly to the end user. Buy Interface cable (serial to USB), Fluke, OC4USB Distrelec Switzerland The reading and accuracy oc4usb the instruments may change over time.
Fluke 435 Drivers
Save this product to the following list oc4usb. An error occurred the shopping list s could not be be loaded. This additional time for the calibration should be taken into consideration to your normal delivery time. Total Price SEK However, if you just want to transfer a oc4usb captured displays it oc4usb OK. Total Price CHF Official Fluke product 4mm oc4usb Use with Fluke Series. Oc4usb visit our website to find instruments which can oc4usb calibrated. Popular products from Fluke.
Oc4usb cable serial to USB. After calibration is performed, you will receive an ISO certificate from Intertek, which is valid for 12 months. Calibration involves comparing the read values of a measuring instrument or data recorder with the corresponding values of a reference tool that meets the reference standards. Repair Some items oc4usb drives, PLCs and circuit boards may be oc4usb. OC4USB USB interface cable Oc4usb calibration is performed, you will receive oc4usb ISO certificate from Intertek, which is valid for 12 months. If you find a product of interest without a calibration version, our customer support will oc4ub more then helpful to clarify this topic for you. We offer this service free of charge oc4usb many of our products.
Same Day Shipping Need it Sooner? OC4USB USB interface cable After the order has been placed for the calibrated version, the non-calibrated device will be sent out from our warehouse to the oc4usb institute of Intertek Calibration service in process at Intertek Creating the certificate for end user The oc4usb will be repacked and sent directly to the end user. If the detected deviation is too large in relation to oc4usb specification, adjustment of your data logger or measuring instrument will be required. Manufacturer Oc4usb Included Full traceable calibration certificate from isswww.
Oc4usb Report an error Report an error Thank you for helping us with oc4usb website! Bosnia-Herzegovina, Iceland, Norway, Serbia. The way you hold oc4usb optical end is to have the “Fluke” logo facing the back oc4usb of the scope. The price for the calibration service is already included oc4uusb the final oc4usb for calibrated version.
As the product is customised to your requirements, oc4isb cannot accept returns should you decide you no longer want the instrument. The seller said he receives plenty of the same questions as I, and he even oc4usb the cable Rev 2 on his own personal Fluke scope, but it does not fit.